  ver : a_3 update : 2016.02.22 ac -dc medical power module mtc30 series 30 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. ( single output ) mtc30-5s MTC30-12S mtc30-15s mtc30-24s max output wattage (w) 25w 30w 30w 30w voltage (note 1) 90-264 vac or 120-370 vdc frequency (hz) 47-440 hz current (full load) 650 ma max. (115 vac) / 400 ma max. (230 vac) inrush current (<2ms,cold start) 30 a max. (115 vac) / 60 a max. (230 vac) leakage current < 0.1ma / 264 vac (touch current) no load input power (<240 vac) <0.15w input external fuse (recommend) 3.15 a slow blow type voltage (v.dc.) 5v 12v 15v 24v voltage accuracy 2% current (ma) max 5000 2500 2000 1250 line regulation (ll-hl) (typ.) 0.5% load regulation (10-100%) (typ.) 1% maximum capacitive load (at 230 vac) 6800uf 1600uf 1200uf 470uf ripple & noise (max.) (note 2) 100mvp-p 150mvp-p 150mvp-p 240mvp-p efficiency (at 230 vac) 84% 89% 86% 86% output hold-up time 10 ms min. over power protection hicc up technique, auto-recovery over voltage protection zener diode clamp protection short circuit protection hiccup mode, indefinite (automatic recovery) isolation input-output (v.ac) 4000v operating temperature -40c?+80c (with derating) storage temperature -40c?+90c max case operating temperature under 115 vac 78c , others 85c temperature coefficient 0.05%/c altitude during operation 5000m humidity up to 95% rh mtbf >250,000 h @ 25c (mil-hdbk-217f) environment atmospheric pressure 70 kpa to 106 kpa dimension (l x w x h) 2.52 x 1.8 x 0.93 inches ( 64.1 x 45.6 x 23.5 mm ) tolerance ? 0.5 mm case material plastic resin (flammability to ul 94v-0) weight 130 g physical cooling method free air convection key features ? switching power module for pcb mountable ? fully encapsulated plastic case ? universal input range 90-264vac ? regulated output and low ripple and noise ? <0.15w no load input power ? isolation class ii ? ce, cb, ul, cul approval ? 3-year product warranty
ver : a_3 update : 2016.02.22 ac -dc medical power module mtc30 series 30 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. ( single output ) mtc30-5s MTC30-12S mtc30-15s mtc30-24s safety approval cul / ul standard: ul 60950-1, can/csa c22.2 no. 60950-1-07 ansi/aami es60601-1 (2005 + c1:09 + a2:10), can/csa-c22.2 no. 60601-1 (2008), 2 x mopp cb standard: iec 60950-1:2005 (2nd edition) + am 1:2009 + am 2:2013 iec 60601-1:2005 (3rd edition) + corr. 1 (2006) + corr. 2 (2007) + am1 (2012) or iec 60601-1 (2012 reprint), 2 x mopp conducted and radiated emi en55011 class b esd en61000-4-2 air 8kv , contact 4kv radiated immunity en61000-4-3 10v/m fast transient en61000-4-4 2kv surge en61000-4-5 1kv conducted immunity en61000-4-6 10vrms pfmf en61000-4-8 30a/m dips en61000-4-11 30% 10ms emc interruption en61000-4-11 >95% 5000ms note 1. this product is not designed for use in critical life suppor t systems, equipment used in hazardous environment, nuclear control systems or other such applications wh ich necessitate specific safety and regulatory standards other the ones listed in this datasheet. 2. ripple & noise are measured at 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor. 3. safety approvals cover frequency 47-63 hz. 4. that ?natural convection? is about 20lfm but is not equal to still air (0 lfm). 5. it's recommended to add varistor 14s471k at l / n input side in parallel. 6. please refer to our pdf file "ac-dc applic ation" on our website: www.archcorp.com.tw mechanical dimension ( top view ) pin# single 1 ac in (n) 2 ac in (l) 3 -dc out 4 no pin 5 +dc out
ver : a_3 update : 2016.02.22 ac -dc medical power module mtc30 series 30 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- derating block diagram


▲Up To Search▲   

 
Price & Availability of MTC30-12S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X