ver : a_3 update : 2016.02.22 ac -dc medical power module mtc30 series 30 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -1- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. ( single output ) mtc30-5s MTC30-12S mtc30-15s mtc30-24s max output wattage (w) 25w 30w 30w 30w voltage (note 1) 90-264 vac or 120-370 vdc frequency (hz) 47-440 hz current (full load) 650 ma max. (115 vac) / 400 ma max. (230 vac) inrush current (<2ms,cold start) 30 a max. (115 vac) / 60 a max. (230 vac) leakage current < 0.1ma / 264 vac (touch current) no load input power (<240 vac) <0.15w input external fuse (recommend) 3.15 a slow blow type voltage (v.dc.) 5v 12v 15v 24v voltage accuracy 2% current (ma) max 5000 2500 2000 1250 line regulation (ll-hl) (typ.) 0.5% load regulation (10-100%) (typ.) 1% maximum capacitive load (at 230 vac) 6800uf 1600uf 1200uf 470uf ripple & noise (max.) (note 2) 100mvp-p 150mvp-p 150mvp-p 240mvp-p efficiency (at 230 vac) 84% 89% 86% 86% output hold-up time 10 ms min. over power protection hicc up technique, auto-recovery over voltage protection zener diode clamp protection short circuit protection hiccup mode, indefinite (automatic recovery) isolation input-output (v.ac) 4000v operating temperature -40c?+80c (with derating) storage temperature -40c?+90c max case operating temperature under 115 vac 78c , others 85c temperature coefficient 0.05%/c altitude during operation 5000m humidity up to 95% rh mtbf >250,000 h @ 25c (mil-hdbk-217f) environment atmospheric pressure 70 kpa to 106 kpa dimension (l x w x h) 2.52 x 1.8 x 0.93 inches ( 64.1 x 45.6 x 23.5 mm ) tolerance ? 0.5 mm case material plastic resin (flammability to ul 94v-0) weight 130 g physical cooling method free air convection key features ? switching power module for pcb mountable ? fully encapsulated plastic case ? universal input range 90-264vac ? regulated output and low ripple and noise ? <0.15w no load input power ? isolation class ii ? ce, cb, ul, cul approval ? 3-year product warranty
ver : a_3 update : 2016.02.22 ac -dc medical power module mtc30 series 30 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -2- electrical specifications all specifications valid at normal in put voltage, full load and +25c after warm-up time unless otherwise stated. model no. ( single output ) mtc30-5s MTC30-12S mtc30-15s mtc30-24s safety approval cul / ul standard: ul 60950-1, can/csa c22.2 no. 60950-1-07 ansi/aami es60601-1 (2005 + c1:09 + a2:10), can/csa-c22.2 no. 60601-1 (2008), 2 x mopp cb standard: iec 60950-1:2005 (2nd edition) + am 1:2009 + am 2:2013 iec 60601-1:2005 (3rd edition) + corr. 1 (2006) + corr. 2 (2007) + am1 (2012) or iec 60601-1 (2012 reprint), 2 x mopp conducted and radiated emi en55011 class b esd en61000-4-2 air 8kv , contact 4kv radiated immunity en61000-4-3 10v/m fast transient en61000-4-4 2kv surge en61000-4-5 1kv conducted immunity en61000-4-6 10vrms pfmf en61000-4-8 30a/m dips en61000-4-11 30% 10ms emc interruption en61000-4-11 >95% 5000ms note 1. this product is not designed for use in critical life suppor t systems, equipment used in hazardous environment, nuclear control systems or other such applications wh ich necessitate specific safety and regulatory standards other the ones listed in this datasheet. 2. ripple & noise are measured at 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor. 3. safety approvals cover frequency 47-63 hz. 4. that ?natural convection? is about 20lfm but is not equal to still air (0 lfm). 5. it's recommended to add varistor 14s471k at l / n input side in parallel. 6. please refer to our pdf file "ac-dc applic ation" on our website: www.archcorp.com.tw mechanical dimension ( top view ) pin# single 1 ac in (n) 2 ac in (l) 3 -dc out 4 no pin 5 +dc out
ver : a_3 update : 2016.02.22 ac -dc medical power module mtc30 series 30 watts http://www.archcorp.com.tw tel: +886-2-26989508 fax: +886-2-26981319 -3- derating block diagram
|